RAE Systems by Honeywell T02-0003-000 AutoRAE 2 Automatic Test and Calibration System, For Use With ToxiRAE Pro Monitor, Configuration: PC Based Via ProRAE Studio II Software
RAE Systems by Honeywell T02-0003-000 AutoRAE 2 Automatic Test and Calibration System, For Use With ToxiRAE Pro Monitor, Configuration: PC Based Via ProRAE Studio II Software
The AutoRAE 2 automatic test and calibration system for RAE systems portable monitors makes instrument testing and calibration compliance as easy as pressing a button. Simply cradle the monitor and the system takes care of calibration, testing, and battery recharging. The AutoRAE 2 system is flexible and modular, and can be configured to efficiently meet your calibration and records management requirements. An AutoRAE 2 system can be as simple as a single cradle deployed in stand-alone mode to calibrate one instrument at a time or as powerful as a networked, controller-based system supporting 10 instrument cradles and 5 distinct calibration gases or gas mixtures.
RAE Systems by Honeywell Automatic Test and Calibration System, Series: AutoRAE 2, 400 mLpm, For Use With: ToxiRAE Pro Monitor, 110 to 240 V AC Input/12 V DC Output, PC Based Via ProRAE Studio II Software, -60 to 60 in WC, Red/Green/Yellow LED Light Indicator, 11.61 in Length, 6-1/2 in Width, 3.91 in D
Features
- Automatic testing, calibration and charging system
- Deployable as a stand-alone cradle or a controller-based system with up to 10 cradles
- Controller with a large, color LCD display
- Networking capability
- Up to 5 calibration gas cylinders can be connected at the same time
- Automatic instrument FW update option
- Instruments data logging file recorded automatically on controller SD card
- Bench-top or wall-mounted use
- Instruments supported: ToxiRAE Pro, QRAE3, MicroRAE, MultiRAE
- Single cradle for all QRAE 3 and ToxiRAE Pro family instruments
- The high-resolution color display on the controller provides a rich, intuitive user experience
- Supports a wide variety of gases, including exotics
- 2 seven-segment LEDs display
- 2 buttons
- 90 dB at 12 in audible alarm
- 3 inlets (1 dedicated fresh air inlet and 2 configurable calibration gas inlets) and 1 exhaust port
- Connectors with 200-series barbs and 1/8 in ID tubing gas port
- Demand flow regulator - 0 to 1000 psig/70 bar
- USB type B port for direct connection to PC
- 5 to 95% relative humidity (non-condensing)
Specifications
The AutoRAE 2 automatic test and calibration system for RAE systems portable monitors makes instrument testing and calibration compliance as easy as pressing a button. Simply cradle the monitor and the system takes care of calibration, testing, and battery recharging. The AutoRAE 2 system is flexible and modular, and can be configured to efficiently meet your calibration and records management requirements. An AutoRAE 2 system can be as simple as a single cradle deployed in stand-alone mode to calibrate one instrument at a time or as powerful as a networked, controller-based system supporting 10 instrument cradles and 5 distinct calibration gases or gas mixtures.
RAE Systems by Honeywell Automatic Test and Calibration System, Series: AutoRAE 2, 400 mLpm, For Use With: ToxiRAE Pro Monitor, 110 to 240 V AC Input/12 V DC Output, PC Based Via ProRAE Studio II Software, -60 to 60 in WC, Red/Green/Yellow LED Light Indicator, 11.61 in Length, 6-1/2 in Width, 3.91 in D