ALLFUSES.COM
ATM30

Mersen Amp-Trap® ATM30 Low Voltage Fast Acting Fuse, 30 A, 600 V AC/DC, 100 kA, Class Midget, Cylindrical Body

Mersen Amp-Trap® ATM30 Low Voltage Fast Acting Fuse, 30 A, 600 V AC/DC, 100 kA, Class Midget, Cylindrical Body

Catalog Number:
Manufacturer: ALLFUSES.COM
Brand: ALLFUSES.COM
Item ID: FUSE ATM30
MPN: ATM30
Min Order Qty: 1

Amp-Trap® midget fast-acting ATM fuses are rated 600 volts AC and DC, with a 100kA interrupting rating. These ratings give the ATM a wide range of applications not covered by other midget fuses. In addition, ratings of 30/35, 30/40 and 30/50 amperes are offered for specific applications such as capacitor protection. These ATM fuses must still be considered 30A fuses because of their dimensions, but are able to withstand much higher inrush currents and tougher duty cycles. (Not for Branch Circuit Protection).

Mersen Amp-Trap® Fast Acting Fuse, Low Voltage, Series: ATM, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Non-Rejection, 30 A, 600 V AC/DC, 100 kA Interrupt, Class: Midget, 12.5 s Response, Ferrule Terminal, Clip Mount, Cylindrical Body, Single Element, Fiber, 13/32 in Dia x 1-1/2 in L Body Size

Sold As: EACH

Features

  • Extended ratings for special protection of capacitors and circuits with high inrush currents
  • 600 VDC ratings for a wide variety of applications including photovoltaic and solar applications
  • Tin-plated copper contact
  • Can be used with UltraSafe™ fuse holders

Specifications

Amperage Rating
30 A
Body Size
13/32 in Dia x 1-1/2 in L
Body Type
Cylindrical
Class
Midget
Element
Single
Indicating/Non-Indicating
Non-Indicating
Interrupt Rating
100 kA
Material
Fiber
Mounting Type
Clip
Rejection/Non-Rejection
Non-Rejection
Response Time
12.5 s
Series
ATM
Terminal Type
Ferrule
Type
Low Voltage
Voltage Rating
600 V AC/DC

Amp-Trap® midget fast-acting ATM fuses are rated 600 volts AC and DC, with a 100kA interrupting rating. These ratings give the ATM a wide range of applications not covered by other midget fuses. In addition, ratings of 30/35, 30/40 and 30/50 amperes are offered for specific applications such as capacitor protection. These ATM fuses must still be considered 30A fuses because of their dimensions, but are able to withstand much higher inrush currents and tougher duty cycles. (Not for Branch Circuit Protection).

Mersen Amp-Trap® Fast Acting Fuse, Low Voltage, Series: ATM, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Non-Rejection, 30 A, 600 V AC/DC, 100 kA Interrupt, Class: Midget, 12.5 s Response, Ferrule Terminal, Clip Mount, Cylindrical Body, Single Element, Fiber, 13/32 in Dia x 1-1/2 in L Body Size

Resources